Denver HVAC Repair

Routine maintenance involves replacing or cleaning the filters if so equipped, and keeping the outside air intake free of debris. After years of service the air exchanger will become crusted with grease and dirt that collects during condensation. Removing this accumulation will probably take solvents or degreasers and require opening up the cabinet and compartments.
The main problem when installing a multi-split system is the laying of long refrigerant lines for connecting the external unit to the internal ones. While installing a separate split system, workers try to locate both units opposite to each other, where the length of the line is minimal. Installing a multi-split system creates more difficulties, since some of indoor units can be located far from the outside. The first models of multi-split systems had one common control system that did not allow you to set the air conditioning individually for each room. However, now the market has a wide selection of multi-split systems, in which the functional characteristics of indoor units operate separately from each other.

One of the easiest maintenance tasks consumers can do themselves is maintaining the filters. Air filters should be inspected and cleaned once a month. This allows for regular monitoring to eventually determine when the filter needs to be replaced. Most filters can be changed every three months if no other problems exist. Maintaining clean and regularly changed filters will not only produce better air quality, but appliances will function more efficiently, which can save on heating and cooling costs. 
IntimatesBras,Lingerie,Lounge & Sleepwear,Panties...3886 Maternity ClothingMaternity Activewear,Maternity Bottoms,M...407 Plus Size ClothingPlus Size Activewear,Plus Size Bottoms,P...1624 Women's AccessoriesWomen's Belts,Women's Eyewear,Women's Gl...8489 Women's ClothingDresses,Leggings,Skirts,Sweaters & Cardi...40981 Women's ShoesBoots & Booties,Pumps & Heels,Women's At...2821
Good Evening HVAC Team, I deeply appreciate your team for getting back to me quickly yesterday evening so I could schedule an appointment for my gf's place(definitely something has been wrong for a while)-- The technician Alberto showed up within the 2 hour window that was appointed to us (WITHIN the 1st half hour!!!). BIG THANK YOU for being honest, and advising us that for some reason the fuse/switch was in the reverse position so the AC unit would not properly turn on. The unit turned back on immediately, and began cooling the house. And then providing advice that the AC/Heating system needed some TLC, and giving us options to save money by purchasing a maintenance plan that included the filters plus cleaning services since we were already being charged for the service today. My personal thanks for being extremely professional, and personable as you entered our home. Solving the technical issue is only part of the job, but providing great Customer Service, and Cost Effective solutions are reasons to recommend you to the people who are looking for the same type of service. Also, it was very convenient that you were able to take my payment over the Phone(FaceTime) since I was not present at the time. Your company website is well organized, and I had no problem reviewing your capabilities as well as how to contact your team. Most important, Tina spoke very highly of you, and made her feel comfortable through the process. SO BOTTOM LINE to other customers looking for HVAC service: LOOK NO FURTHER!!! If you have a AC/Heater Issue, give this the HVAC company a call, or email-- You won't be disappointed. Kind Regards, Michael
Believe it or not, the evaporator coils inside the AHU (Air Handling Unit) are freezing. You may notice the refrigerant lines on the condenser or at the AHU are frozen with ice build-up. The frost or ice builds up on the evaporator coils and blocks air flow (low air flow and no cooling are a sign of a low charge). A low refrigerant charge will cause the evaporator coil to operate at or below freezing. Since the coil typically operates below the dew point, it draws condensation out of the air. When the evaporator coil begins operating below freezing all this condensation freezes to the evaporator coil and the unit stops cooling.

Natural ventilation is a key factor in reducing the spread of airborne illnesses such as tuberculosis, the common cold, influenza and meningitis. Opening doors, windows, and using ceiling fans are all ways to maximize natural ventilation and reduce the risk of airborne contagion. Natural ventilation requires little maintenance and is inexpensive.[19]


Monday the following week, no phone calls, or follow up.  I call to get an update and am told that they cannot install my system because they don't have time.  I ask what does that mean, one year? One week? Until the end of summer they say.  What does that mean I ask?  They say at the end of September.  I say thank you for wasting 1 month of my time.
I originally took off one star because of the SNAFU with getting the part ordered. When Alberto called me on the phone he admitted the person had "gotten busy with other things" and apologized. THAT was taking the high road and I was impressed by that. Sadly, for reasons I won't guess at, Alberto has decided to take the low road in his comments and imply that they got the part as quickly as possible. Well, we called at 2:30 so did someone spend six and a half hours finding the part?? That seems very doubtful. As for the price I think my review was fair in stating what value we got for what I deemed to be a slightly higher price than others might charge. I did not take any stars off for the price, and still am not, but I am taking another star off because of Alberto's comments, which are deceptive and not the same thing he told me in person. Alberto, I suggest you stick with the high road in the future.
“We had a great experience with Robinson’s! The office staff, then the gentleman who helped me with questions over the phone and Kyle, our service tech, were all great and very easy to work with. They gave me a time frame for when to expect Kyle the same day. A phone call to let me know he was on his way. A text with picture so I knew who to be expecting. Kyle arrived on time and was very knowledgeable and friendly. He did a great job. You could tell he liked his job. Prices were reasonable. We will be using and recommending Robinson’s Air – Wichita Falls in the future.”
Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.

A career in this field may require you to meet certain licensing, training, and other requirements that can vary by vocation and state. You should check with your state, local government, and/or licensing board to find out which requirements may be applicable in your state. Click here for contact information on state licensing/regulatory boards and certain professional licensing information.


Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.
Air conditioner inverter Air door Air filter Air handler Air ionizer Air-mixing plenum Air purifier Air source heat pumps Automatic balancing valve Back boiler Barrier pipe Blast damper Boiler Centrifugal fan Chiller Condensate pump Condenser Condensing boiler Convection heater Cooling tower Damper Dehumidifier Duct Economizer Electrostatic precipitator Evaporative cooler Evaporator Exhaust hood Expansion tank Fan coil unit Fan heater Fire damper Fireplace Fireplace insert Freeze stat Flue Freon Fume hood Furnace Furnace room Gas compressor Gas heater Gasoline heater Geothermal heat pump Grease duct Grille Ground-coupled heat exchanger Heat exchanger Heat pipe Heat pump Heating film Heating system High efficiency glandless circulating pump High-efficiency particulate air (HEPA) High pressure cut off switch Humidifier Infrared heater Inverter compressor Kerosene heater Louver Mechanical fan Mechanical room Oil heater Packaged terminal air conditioner Plenum space Pressurisation ductwork Process duct work Radiator Radiator reflector Recuperator Refrigerant Register Reversing valve Run-around coil Scroll compressor Solar chimney Solar-assisted heat pump Space heater Smoke exhaust ductwork Thermal expansion valve Thermal wheel Thermosiphon Thermostatic radiator valve Trickle vent Trombe wall Turning vanes Ultra-low particulate air (ULPA) Whole-house fan Windcatcher Wood-burning stove
A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
In 1906, Stuart W. Cramer of Charlotte was exploring ways to add moisture to the air in his textile mill. Cramer coined the term "air conditioning", using it in a patent claim he filed that year as an analogue to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories, controlling the humidity so necessary in textile plants. Willis Carrier adopted the term and incorporated it into the name of his company.[10]

Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.
×