Denver HVAC Repair

Replacing your old heating and cooling equipment with new, energy-efficient models is a great start. But to make sure that you get the best performance, the new equipment must be properly installed. In fact, improper installation can reduce system efficiency by up to 30 percent - costing you more on your utility bills and possibly shortening the equipment's life. Learn more.
Waited a week for technician who showed up for less than 15 minutes and told me that my air filters were dirty and I needed to experiment with thermostats to be comfortable. Thermostat shows temp at 75 when set on 71. Did what he instructed and still had problems when I realized unit was short cycling. When I called technician he told me I would have to place a new request for service. He gave me the office number and hung up on me. By the time I called office he had called in and said he refused to come back out. The operator would not give me business owners name and could not tell me why technician refused to return although they did say they would refund the fee for service call. Telephone rep yelled at me.
Outside of your home is an outdoor unit, which is called a condenser. Inside the condenser is a compressor, a condenser coil, and a large fan. The compressor pumps cool refrigerant to an evaporator coil located either in the air handler or just outside the furnace. The evaporator coil gets really cold so that when the blower or furnace pushes warm air past it, the air is cooled. This cool air is then distributed throughout your home through a series of air ducts. Heat is absorbed by the evaporator coil, which warms the refrigerant moving through the coils. This warm refrigerant is then pumped back outside to the condenser coil, where a giant fan cools it off allowing the warm air to escape. This cycle is repeated until your thermostat detects that your home has reached the temperature you set it to.

If the AC doesn’t turn off, it may be time to clean the condensing unit. Dirty condenser coils won’t give off heat efficiently and will keep the unit running.  Another possibility: The contacts on the outdoor run relay may have welded together—something that can happen over time because of frequent electrical arcing at the relay. Before checking the run relay, turn off the power to the furnace and the condensing unit. Next, disassemble the relay and pry apart the contacts. This should do the trick until you buy a replacement—which you should do soon.

Some types of filters are reusable; others must be replaced. They are available in a variety of types and efficiencies. Clean or replace your air conditioning system's filter or filters every month or two during the cooling season. Filters may need more frequent attention if the air conditioner is in constant use, is subjected to dusty conditions, or you have fur-bearing pets in the house.
The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.
Jiffy Lube does not recommend servicing systems with detected leaks or damage. The Jiffy Lube AC service is designed for periodic maintenance rather than AC repair, but rest assured Jiffy Lube can recommend the next steps to be taken to get your AC system up and running. Early detection of leaks or damage to your vehicle AC system can save you time and money, keeping you and everyone in your vehicle cool and worry free.
"Our Pro was the most courteous and informative gentleman that we have had the pleasure to work with, was great. He let us know immediately what the problem was and what the cost to fix it would be. Also, he let us know how to maintain and extend the life of our washer. He was very personable and made us very comfortable with the process. We would have him back in a heartbeat if anything ever goes wrong again. It was the best experience we have ever had with a appliance repair service."
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
Combined, our people can offer decades worth of HVAC service and installation experience in Tucker, which we bring to every single job we do. Our staff believes wholeheartedly that reliability, passion, and expertise are critical to providing our customers with good service, and we can do that for both residential and commercial clients. For commercial buildings, in which safety and maintenance are key values, we are the best provider for your needs. From weekly safety meetings to provided protective equipment and mandatory site risk assessments, our technicians can install, repair, and maintain all commercial HVAC products under the purview of the very highest safety standards. In addition, we can give you a one-year, 100% Satisfaction Guarantee* on commercial service. Most companies only guarantee their work for the first few months, but we believe that we can, and will, do an exemplary job for all our customers in Tucker.
Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.
I'll give props to HVAC Service for being available quickly and having Saturday and Sunday appointments. Tony fixed our air conditioner and was professional. So why only 2 stars? Because we sent the receipt into our homeowner association to see if we could get reimbursed for some costs, and the property manager said that we paid THREE times more than we should have. We got conned. I advise you to call HVAC Service, but also shop around and get other estimates. Learn from our mistake!
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.

First, it is wise to stick with a company that specializes in HVAC services. While many general handyman companies may do some things with AC units, a company that specializes in air conditioning and heating is always a better option. Because air conditioning repairs can be quite costly, depending on the particular problem, it is best to work with highly trained HVAC professionals to ensure quality work.
Call Miller's Air Conditioning & Heating at (925) 583-6387 and always speak with a live and helpful member of our team, who will immediately focus on your requirements.  While our competitors punch a strict time clock, we realize heating and cooling challenges often arise outside of regular business hours.  Rather than leave a message on a machine, take advantage of personalized service and the prompt response of radio dispatched trucks.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
×