Denver HVAC Repair

To be honest, an HVAC technician’s work goes beyond more than installation, maintenance and repair. Most people are increasingly spending more time inside the home, so indoor air quality, home energy savings and total comfort have become even more important. There are several choices and solutions when it comes to HVAC systems, and our experts will consult with you every step of the way and work with you to achieve your goals.


R22 (also known as HCFC-22) has a global warming potential about 1,800 times higher than CO2.[61] It was phased out for use in new equipment by 2010, and is to be completely discontinued by 2020. Although these gasses can be recycled when air conditioning units are disposed of, uncontrolled dumping and leaking can release gas directly into the atmosphere.
Additionally, new technology and government requirements are pushing manufacturers to build more energy efficient HVAC equipment. January 2006 we observed the end of 10 SEER units with 13 SEER air conditioning units mandated by the government. This only makes sense; however, with the higher efficiency, there comes complexity in the technology engineered into the equipment. A problem can be difficult to troubleshoot and diagnose and may require more time than the lower efficiency, less complex units.
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40-$240.
Harrisburg, PA appliance repair Appliance repair Myrtle Beach Appliance repair Waterloo Appliance repair Port Richey 6929 S Memorial Dr appliance repairs Appliance repair Schaumburg Appliance Maintenance Book snow blower maintenance appointment Schedule Appointment for HVAC Maintenance Carpet Cleaning Services Air Duct Cleaning Services Handyman Service Riding Mower Maintenance Sears Warranty and Satisfaction Guarantee Heating and Cooling Home Renovation Tulsa Window Replacement Home Kitchen Design Roof Installation & Replacement Service Home Improvement Cabinet refacing & replacement home improvement
Looking to cut down your home heating and cooling costs? Trane TruComfort™ Variable speed systems do just that. Trane TruComfort™ runs at the speed necessary to keep your home continuously comfortable – automatically adjusting up and down within one-half degree of your setting and constantly circulating air. The result? Running at up to 21 SEER (Seasonal Energy Efficiency Ratio) – which means affordable residential heating and air for you.

Our company has been serving Woodbridge and the Northern Virginia region since 1979. We don’t compromise on quality — our team members pride themselves on providing the top-quality service each and every time. We attribute our success to the fact that we’re responsive to our customers’ needs, no matter if they’re residential or commercial, large or small. Whether you need routine maintenance or a complete system installation, our team of trained technicians is at your beck and call, and we’re prepared to deliver quality services and products at an affordable price. We live by the time-tested motto, “Do the job right the first time.”
I have no idea what a barrel is??? In chilled water systems the evaporator and condensers sometimes use what is called a chiller barrel for the evaporator and/or the condenser but for most residential system it is a rarity to find a chilled water system installed. Are you talking about a commercial system chiller. 7.1 KW is not a very big system but they do exist in light commercial and as mentioned in residential.
A career in this field may require you to meet certain licensing, training, and other requirements that can vary by vocation and state. You should check with your state, local government, and/or licensing board to find out which requirements may be applicable in your state. Click here for contact information on state licensing/regulatory boards and certain professional licensing information.
In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-)humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3]

Not obvious is the fact that they need maintenance routinely, just like any other machine. The filter, usually located behind the front grill, needs to be washed. The condenser coil at the back of the unit can accumulate a lot of debris, and might require a special chemical bath. All air conditioning systems, large or small, need good air flow across the evaporator coil and the condenser coil. Efficiency and performance drop rapidly as air flow decreases. Lose enough air flow and the unit will burn out. Rodents can nest inside when not in use, and can foul up the unit in many ways. Wasps and hornets, as well as the honey bee find finned coils to be comfortable nesting places. Nests and dead insects can ruin the air conditioner.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
×