2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 


Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.
Tony was very good - appointment took a while to book, but that's understandable, since they have built a great business and have lots of people calling them. Tony came this Sunday morning, and once he saw the HVAC unit, knew exactly what the issue was - fixed it in under 20 mins, and my AC was back to normal Pricing is fair - parts, labor and diagnostic fee and tax I would definitely recommend him to anyone needing his services. He's honest, very nice to deal with even made my toddler son smile. 5 STARS ALL THE WAY!

One problem occurred on Monday.  When we called at 2:30 in the afternoon to check on status, we were told that "the tech is on the phone with the parts supplier now".  It seems more likely that they had forgotten about us and our call woke them up.  But even if true, why the heck did they wait until 2:30 to order the part?  Maybe if they had ordered it in the morning they could have had it the same day.  So I'm taking off one star for that.

When your heating or cooling system finally breaks, it’s not usually during convenient office hours or in mild weather. Your HVAC unit has to work harder during extreme conditions like a sweltering summer day or freezing winter night, so it is much more likely to fail during those times. R.S. Andrews has our customers’ safety and comfort as our priority, so we offer service 24 hours a day for emergencies. No matter when your equipment fails, you can count on us to repair it quickly and efficiently!

In a thermodynamically closed system, any power dissipated into the system that is being maintained at a set temperature (which is a standard mode of operation for modern air conditioners) requires that the rate of energy removal by the air conditioner increase. This increase has the effect that, for each unit of energy input into the system (say to power a light bulb in the closed system), the air conditioner removes that energy.[30] To do so, the air conditioner must increase its power consumption by the inverse of its "efficiency" (coefficient of performance) times the amount of power dissipated into the system. As an example, assume that inside the closed system a 100 W heating element is activated, and the air conditioner has a coefficient of performance of 200%. The air conditioner's power consumption will increase by 50 W to compensate for this, thus making the 100 W heating element cost a total of 150 W of power.
Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
Many HVAC maintenance companies offer annual servicing contracts for preventative maintenance. Such contracts cost anywhere from $100-$150 per year, and cover annual visits in which standard maintenance tasks are performed. Some companies will allow you to make monthly payments for your maintenance contract, and will provide you with discounts around 15% if you hire them when you need your unit repaired.
The coil is usually made of copper tubing with aluminum fins, but some manufacturers use aluminum tubing. Its purpose is to transfer heat as rapidly as possible. Pressure inside the coil can exceed 400 psi. during extremely warm weather conditions. The cleaner it is kept, the better it transfers heat. Rinsing with a garden hose occasionally when the unit is not running will help keep it operating efficiently. After many years of use it may be necessary to put special chemicals on to clean it.
We moved into a new home and had issues with the heating ducts in one of the rooms. We called HVAC based on other yelp reviews. Overall, everyone we dealt with were friendly, professional and knowledgeable: From the people on the phone managing the schedule to the those performing the work in our house. The day before the scheduled work we asked if additional work could be done (clothes dryer duct cleaning), which they were able to accommodate. The people working at the house were on time, very polite, took great care to keep the house clean during the entire job and explained everything when they were finished. I will certainly use HVAC again.
Tony was very good - appointment took a while to book, but that's understandable, since they have built a great business and have lots of people calling them. Tony came this Sunday morning, and once he saw the HVAC unit, knew exactly what the issue was - fixed it in under 20 mins, and my AC was back to normal Pricing is fair - parts, labor and diagnostic fee and tax I would definitely recommend him to anyone needing his services. He's honest, very nice to deal with even made my toddler son smile. 5 STARS ALL THE WAY!
This information is not intended as an offer to sell, or the solicitation of an offer to buy, a franchise. It is for information purposes only. Read More Currently, the following states regulate the offer and sale of franchises: California, Hawaii, Illinois, Indiana, Maryland, Michigan, Minnesota, New York, North Dakota, Oregon, Rhode Island, South Dakota, Virginia, Washington, and Wisconsin. If you are a resident of or want to locate a franchise in one of these states, we will not offer you a franchise unless and until we have complied with applicable pre-sale registration and disclosure requirements in your state. Read Less Aire Serv is a registered trademark of Aire Serv LLC © Aire Serv | All rights reserved | All Aire Serv franchise locations are independently owned and operated.

If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
×