If your compressor doesn’t have an overload button and you hear it humming or buzzing, poke a screwdriver or stick down through the top grille and try to spin the fan blades clockwise. If doing this gives the fan enough of a boost to get it going, the unit has a faulty capacitor that must be replaced. See How to Test and Replace an AC Run Capacitor, above.
Absolutely horrible service dont show or call within there appointment window, half to blow up the o...wners phone after there appointment window to get any answers why. And then it takes another 2 hours for there tech to get there after you were told it would be only an hour. Horrible customer service even though it was a Saturday and they made the appointment. But the tech was very professional. Never recommend them only had to use them cause of insurance See More
For details about apprenticeships or other work opportunities, contact the offices of the state employment service, the state apprenticeship agency, local contractors, or local union–management HVACR apprenticeship committees. Apprenticeship information is available from the U.S. Department of Labor’s Apprenticeship program online or by phone at 877-872-5627.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).

In addition to the information below, see these two articles for the general care and maintenance of your air conditioner: Preparing Your Air Conditioner for Summer and How to Replace Furnace & AC Filters. Most noteworthy, you should replace the filters at least twice a year, before the heating and cooling seasons. For information on furnace problems, please see Furnace Not Working.
In the UK, the Ozone Regulations[62] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.

I awoke to a smoky smell from my heater and called HVAC service Heating & Air . I called HVAC and I was given an appointment that afternoon. Their technician arrived promptly and was totally knowledgeable and courteous. He had the new motor and starter on his truck and after a total replacement I now have my morning heat back!! I would use them over n over and they were very competitive in their pricing.
At James Heating & A/C, Inc, heating and cooling isn’t just our job, it’s our passion. We strive to provide you with high quality HVAC service in Lexington. No matter the size of the problem or time of day, you can count on us to get the job done properly. After all, James Heating & A/C, Inc has been working in the community since 1967, bringing comfort to our customers right when they need it.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
×