Denver HVAC Repair

Was not satisifed with this company.  This person came out and took 10 minutes only to tell me that my unit would not last for a year and that I needed to have it replaced!  I'm not sure if he was very knowlegable or if he was just plain lazy and do not even try to fix the problem.  He just wanted to install a brand new system because he was both and of course, that's much more money for him!


We'll help » Can't find a model number? Using a model number is the fastest way to find your part. Shop now » RANGE PARTS FOR EVERY MAJOR BRAND Heating Elements, Ignitors, Cooktops and More. Learn More » A HEALTHY AND HAPPY LAWN Easy Guide To The Best Lawn On The Block. Watch now » Expert repair videos Don’t Worry. With over 3000 how-to videos we’ve got you covered.Learn More » Read More » CUSTOMER TESTIMONIALS Our customers save time, money & become DIY repair experts.
Heaters exist for various types of fuel, including solid fuels, liquids, and gases. Another type of heat source is electricity, normally heating ribbons composed of high resistance wire (see Nichrome). This principle is also used for baseboard heaters and portable heaters. Electrical heaters are often used as backup or supplemental heat for heat pump systems.
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
If you have an older central air conditioner, you might choose to replace the outdoor compressor with a modern, high-efficiency unit. If you do so, consult a local heating and cooling contractor to assure that the new compressor is properly matched to the indoor unit. However, considering recent changes in refrigerants and air conditioning designs, it might be wiser to replace the entire system.
BGE HOME HVAC repair technicians are thoroughly trained and certified to work on all major brands of heating and air conditioning equipment. When your system breaks down and needs a heating and air conditioning repair, you want to call someone you can trust. Need air conditioning service in the middle of the night? Emergency heating and cooling HVAC service is available 24 hours a day by calling 888-243-4663.
Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[55] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]
How often you should clean your air ducts depends on your situation. If you or someone in the home has asthma or is acutely allergic to certain airborne materials or pollen, regular duct cleaning may be helpful. The Environmental Protection Agency doesn’t have an official position on the necessity of air duct cleaning unless the ducts have been contaminated by rodents, insects or mold, or you are aware of particles blowing out through the vents. The EPA recommends you have your air ducts cleaned on an as-needed basis. The National Air Duct Cleaners Association (NADCA) suggests having air ducts cleaned every three to five years.
Need Air Conditioner Repair or Furnace Repair? Look no further. The HVAC experts at Allatoona Heating and Air are here to help you today. We have the training and experience necessary to handle all sorts of heating and air conditioning issues for all brands of heating and air equipment. We’re not limited to repairs either. Our HVAC technicians can help you with repairs, service, maintenance, replacement or installation of heating and air conditioning equipment for your home or office. Call us today!

Be cautious with companies that offer “whole house air duct cleaning,” urges the NADCA. The company may be using unscrupulous tactics to upsell you once they get started. Before any work begins, always clarify in writing what the job entails and what the cost will be. To protect yourself against fraud, read customer reviews and verify that your HVAC cleaning service has applicable licenses and certifications.


Fast forward 1 year and 1 week and the circuit board that HVAC Service had installed has failed again. They came out and said that it failed from water condensation dripping onto it, so we needed to replace it and reroute the pipes to prevent future water damage.  That would cost double what I paid last year.  Why didn't they fix the problem last year at the initial repair instead of putting in a circuit board that was bound to fail again?!? They were strongly recommending that the furnace be completely replace for a huge fee to avoid the same thing happening again.  I paid $59 for them to tell me they didn't fix it right last year. This didn't feel right, so I sought a second opinion.
In 1820, English scientist and inventor Michael Faraday discovered that compressing and liquefying ammonia could chill air when the liquefied ammonia was allowed to evaporate. In 1842, Florida physician John Gorrie used compressor technology to create ice, which he used to cool air for his patients in his hospital in Apalachicola, Florida. He hoped to eventually use his ice-making machine to regulate the temperature of buildings. He even envisioned centralized air conditioning that could cool entire cities. Though his prototype leaked and performed irregularly, Gorrie was granted a patent in 1851 for his ice-making machine. Though his process improved the artificial production of ice, his hopes for its success vanished soon afterwards when his chief financial backer died and Gorrie did not get the money he needed to develop the machine. According to his biographer, Vivian M. Sherlock, he blamed the "Ice King", Frederic Tudor, for his failure, suspecting that Tudor had launched a smear campaign against his invention. Dr. Gorrie died impoverished in 1855, and the dream of commonplace air conditioning went away for 50 years.[citation needed]
Focus first on sealing ducts that run through the attic, crawlspace, unheated basement, or garage. Use duct sealant (mastic) or metal-backed (foil) tape to seal the seams and connections of ducts. After sealing the ducts in those spaces, wrap them in insulation to keep them from getting hot in the summer or cold in the winter. Next, look to seal any other ducts that you can access in the heated or cooled part of the house. See our Duct Sealing Fact Sheet (787KB) for more information.
Before you reach out to local HVAC companies, jot down a few notes. Know the model of your unit and see if it’s under warranty. If so, call the manufacturer first. Then, get multiple quotes for the project in question. Never get less than two quotes for any home remodeling project. Once received, compare all and make sure all include the same work. Check referrals and certifications before making a final decision.
Modern refrigerants have been developed to be more environmentally safe than many of the early chlorofluorocarbon-based refrigerants used in the early- and mid-twentieth century. These include HCFCs (R-22, as used in most U.S. homes before 2011) and HFCs (R-134a, used in most cars) have replaced most CFC use. HCFCs, in turn, are supposed to have been in the process of being phased out under the Montreal Protocol and replaced by HFCs such as R-410A, which lack chlorine.[14] HFCs, however, contribute to climate change problems. Moreover, policy and political influence by corporate executives resisted change.[15][16] Corporations insisted that no alternatives to HFCs existed. The environmental organization Greenpeace provided funding to a former East German refrigerator company to research an alternative ozone- and climate-safe refrigerant in 1992. The company developed a hydrocarbon mix of isopentane and isobutane, but as a condition of the contract with Greenpeace could not patent the technology, which led to its widespread adoption by other firms.[17][18][19] Their activist marketing first in Germany led to companies like Whirlpool, Bosch, and later LG and others to incorporate the technology throughout Europe, then Asia, although the corporate executives resisted in Latin America, so that it arrived in Argentina produced by a domestic firm in 2003, and then finally with giant Bosch's production in Brazil by 2004.[20][21]
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
If your air conditioner’s condenser coils, which are located in the outdoor unit, freeze up, your system will not run properly. Poor airflow through your cooling system can cause ice to form on the coils. Obstructions are typically the cause – such as dirty air filters or blocked return air ducts. Low refrigerant could also be the cause, requiring a refrigerant charge. A home AC repair technician can diagnose the issue behind your frozen coils, resolve it, and safely thaw your coils to restore cooling in your home.”
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
×