Denver HVAC Repair

Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.
The coil is usually made of copper tubing with aluminum fins, but some manufacturers use aluminum tubing. Its purpose is to transfer heat as rapidly as possible. Pressure inside the coil can exceed 400 psi. during extremely warm weather conditions. The cleaner it is kept, the better it transfers heat. Rinsing with a garden hose occasionally when the unit is not running will help keep it operating efficiently. After many years of use it may be necessary to put special chemicals on to clean it.

Children's Jewelry386 Diamond JewelryBracelets,Collections & Sets,Diamond Acc...4118 Fashion JewelryBracelets,Earrings,Fashion Collections &...42847 Fine Metal JewelryBracelets,Collections & Sets,Earrings,Ne...6833 Gemstone & Pearl JewelryBracelets,Collections & Sets,Earrings,Ne...9744 Jewelry Accessories & StorageBoxes & Holders,Cleaners & Accessories516
The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.

The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
No matter where you bought your air conditioning system, we can repair it. We have years of experience working with all the best central air conditioner brands such as Kenmore, Carrier. Trane, Goodman, and Rheem. As a result, you can rest assured we’re familiar with your air conditioning system and we have the parts you need to complete a successful air conditioner repair.

Start with your utility company; they can help a great deal. Comparing previous bills isn't always a good measure, as the weather is never exactly the same month to month. Instead, if you take your energy bill and divide it by the square footage of livable space in your home, don't count areas like unfinished garages or basements -- you can calculate how much you are spending to heat or cool each square foot of your home. Your energy provider can tell you what the average cost per square foot is in your region for that same period of time so you can compare apples to apples.


Ventilation, air conditioning and heating systems require regular maintenance for them to work efficiently. You’ll likely need tune-ups and repairs for them at some point during their lifespan. However, no matter how much preventative maintenance you put into your HVAC system, there comes a time when repairs aren’t enough anymore and it’s time for a replacement.

In the UK, the Ozone Regulations[62] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
When central air conditioning service fails during a heat spell, you may have to wait days for an HVAC repair technician or a ac contractor to show up, and you’ll probably pay at least several hundred for the repair. But if you’re comfortable working around electricity and are willing to spend about $50 on parts, you can probably repair your air conditioning service yourself in about two hours and save about $225 on parts markup and labor.
×