Denver HVAC Repair

Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.

You have an incredible team! My suite has had major issues constant backups. In the last few months we had a horrible flood that caused us thousands of dollars in repairs. Your team was so attentive and took care of all the repairs. Just yesterday another back up called them immediately and like quick responders they were there to take of it! A huge thank you from my La Costa providers and staff! We appreciate your hard and dedicated work!
With colder weather on its way back to Waldorf, furnace and heating repair may not be the first thing you think about, but maybe it should be. Sure, it’s easy for us to sit here and tell you to schedule annual furnace service, but it’s only because we want to help you avoid a heating breakdown during the coldest day of the month in Waldorf. Day or night, our HVAC experts are here to make sure you have a comfortable home, and can help get your furnace back running in little time.
As one of the most trusted commercial HVAC service companies in the Midwest, not only will you receive prompt service, you won’t have to worry about our teams’ knowledge and corrective service capabilities. In the last 18 months, we’ve performed more than 3,790 mechanical preventive maintenance inspections. Whether you're in need of basic air conditioner maintenance or full commercial heating and air conditioning repair, we have yet to find a deficiency we can't fix.

Our heating and cooling maintenance plans include: 2 preventative maintenance visits per year (1 heating, 1 cooling), priority service, 15% off repairs, including parts, labor and refrigerant, 20% off diagnostic fees, no overtime charges on emergency service, and a 1-year guarantee on all repairs and modifications, an upgrade over the standard 90-day warranty. Sign up today and have one less thing to worry about in your home!
As a Carrier Factory Authorized Dealer, Edwards Heating & Air provides superior quality products and workmanship to home and business owners in Acworth and across Acworth, Alpharetta, Cummings, Cartersville, Kennesaw & Woodstock, GA.  Our NATE-certified technicians adhere to strict installation and service procedures, and are uniquely qualified to recommend the most cost-effective solutions to meet your exact needs and expectations.  Whether you are in the market for an HVAC system for new construction, a replacement unit, ductless options, heat pumps, or air conditioning, Edwards Heating & Air ensures a refreshingly cool and healthy home and work environment.  Through accurate sizing, precision installation, and conscientious maintenance, we help you enjoy maximum return from your investment and reliable operation, year after year.  For any cooling challenge you may face, the team from Edwards Heating & Air are your problem solvers, and we are always here when you need us, 24 hours a day, 7 days a week.
Next, consider the age of your unit. Remember, as we mentioned earlier, that the average life of a furnace is around 15 to 20 years. In some cases, during the installation process, your licensed and trained technician will write down the installation date right on the unit. If not, you can check inside the chamber door for a metal identification plate containing the serial and model numbers. You can then call the customer service line of the manufacturer and ask for the manufacture date of the unit.

Believe it or not, the evaporator coils inside the AHU (Air Handling Unit) are freezing. You may notice the refrigerant lines on the condenser or at the AHU are frozen with ice build-up. The frost or ice builds up on the evaporator coils and blocks air flow (low air flow and no cooling are a sign of a low charge). A low refrigerant charge will cause the evaporator coil to operate at or below freezing. Since the coil typically operates below the dew point, it draws condensation out of the air. When the evaporator coil begins operating below freezing all this condensation freezes to the evaporator coil and the unit stops cooling.

Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[26]
The heat pump gained popularity in the 1950s in Japan and the United States.[13] Heat pumps can extract heat from various sources, such as environmental air, exhaust air from a building, or from the ground. Initially, heat pump HVAC systems were only used in moderate climates, but with improvements in low temperature operation and reduced loads due to more efficient homes, they are increasing in popularity in cooler climates.
Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.
×