Denver HVAC Repair

Consequently, this water must exit the air handler—typically through plastic pipe or a drain tube. That drain tube goes directly outside, often terminating near the compressor, or to a floor drain or to a small electric “condensate pump” located by the air handler. Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain.
Our heating and cooling maintenance plans include: 2 preventative maintenance visits per year (1 heating, 1 cooling), priority service, 15% off repairs, including parts, labor and refrigerant, 20% off diagnostic fees, no overtime charges on emergency service, and a 1-year guarantee on all repairs and modifications, an upgrade over the standard 90-day warranty. Sign up today and have one less thing to worry about in your home!

The Chartered Institution of Building Services Engineers is a body that covers the essential Service (systems architecture) that allow buildings to operate. It includes the electrotechnical, heating, ventilating, air conditioning, refrigeration and plumbing industries. To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering, electrical engineering or mechanical engineering. To become a full member of CIBSE, and so also to be registered by the Engineering Council UK as a chartered engineer, engineers must also attain an Honours Degree and a master's degree in a relevant engineering subject.
If the air conditioner on your thermostat set low, and you aren't feeling cool air, it could be that debris is blocking the condenser. Check on your system outside and remove any tree branches or leaves from around it. Debris can easily obstruct air flow, so make sure the area around your air conditioning unit is clean and trimmed back. Make sure your filter is clean. A buildup of dirt and dust can cause poor air circulation.

Some service providers may recommend repairs and maintenance tasks that are not needed. A savvy consumer who has researched how an HVAC system works and is familiar with most common maintenance tasks will quickly know the difference between necessary tasks and add-on services that drain the wallet. If a heating or cooling problem occurs, appliance service manuals typically contain troubleshooting tips and other information that may be helpful in identifying or even resolving the problem without calling a repairman. Online HVAC guides may also be helpful to a consumer who wishes to become more familiar with how an HVAC system works and potential signs of disrepair. 
The condenser fan moves air across the coil to increase the transfer of heat. It is critical to the system. Obstructing the flow of air will not only reduce efficiency, but can lead to compressor failure. Keep debris and objects away from the coil and fan to allow maximum air flow. Some condenser fan motors have sealed bearings, others need lubrication. Damage to the fan can occur if removed improperly. Have a qualified serviceman handle the lubricating if needed.
Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
Most of the time, diagnosing problems is simple and other times it can be a complicated process where the HVAC technician calls in another HVAC technician. The technician may call in an HVAC manufacturer representative. Residential and commercial heating and cooling is important and you want the best possible HVAC air conditioning and heating service. It does not matter whether you have a Carrier Air Conditioner, Trane Air Conditioners, or need a replacement, whatever, it is best to get a qualified technician to look at your system before a decision is made to repair or replace the air conditioner or heat pump systems.
At Sky Heating & Air Conditioning, we understand that HVAC services can really hurt your budget. Many times, you don’t expect to make such large purchases until an emergency arises. We never want you to feel that you cannot afford your comfort and safety. We offer flexible financing options through the Home Project credit card from Wells Fargo, with approved credit. Head over to our financing page to apply, or give us a call for more information!
Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]

We service, repair and install most every type of hvac system whether it’s gas, electric or oil, on hvac systems (furnaces, heatpumps air conditioning untis and boilers) by Trane, Bryant, York, Goodman, Lennox, Rheem, Panasonic, Fujitsu and many more.  Our service area is mainly around the I-97 to Rout 32 corridor specifically Annapolis, Crownsville, Severna Park, Millersville, Gambrills, Crofton, Odenton, Severn, Fort Meade, Jessup, Elkridge through Columbia, MD.


Tony from HVAC came out on Sunday morning and did a fantastic job of immediately diagnosing the issue, quickly fixing the problem, and honoring the coupons I had.  When I initially called on Saturday morning, I had a lot of trouble with their answering service getting their wires crossed with their technicians.  However, Tony called me back and made it right.  He even pointed out an issue that is in the horizon that I should look at (without charging me extra or telling me I had to fix it right now). Great service!

One of the most important ways to maintain the efficiency of your air conditioner is to check on its efficiency periodically throughout the year. In addition to changing your air filters every three months, having a professional heating and cooling professional service your air conditioner before the peak of summer ensures you're not overlooking potential problems. The thorough inspection and tune up of your air conditioner is well worth the low maintenance cost.


Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
×