In modern buildings, the design, installation, and control systems of these functions are integrated into one or more HVAC systems. For very small buildings, contractors normally estimate the capacity and type of system needed and then design the system, selecting the appropriate refrigerant and various components needed. For larger buildings, building service designers, mechanical engineers, or building services engineers analyze, design, and specify the HVAC systems. Specialty mechanical contractors then fabricate and commission the systems. Building permits and code-compliance inspections of the installations are normally required for all sizes of building.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
The most important maintenance task that will ensure the efficiency of your air conditioner is to routinely replace or clean its filters. Clogged, dirty filters block normal airflow and reduce a system's efficiency significantly. With normal airflow obstructed, air that bypasses the filter may carry dirt directly into the evaporator coil and impair the coil's heat-absorbing capacity. Replacing a dirty, clogged filter with a clean one can lower your air conditioner's energy consumption by 5% to 15%.
With a modern heat pump system installation, you’ll enjoy benefits such as exceptional efficiency and maximum temperature control all year round. These innovative systems combine both heating and cooling into one compact system. The technicians from Sky Heating & Air Conditioning are highly qualified and experienced in heat pump maintenance, repairs, and installations, so you can feel confident in our services. We specialize in WaterFurnace geothermal heat pump systems, which offer unprecedented efficiency and energy savings. Browse our website or give us a call today to learn even more!
Low refrigerant charges take away from the life of the compressor. The compressor is cooled from the return refrigerant vapor. When there is a low charge there are fewer vapors to cool the compressor, therefore it runs hotter. Any compressor (or electric motor for that matter) which runs above the recommended temperature range will have a shorter life span and cost more to operate.
If your air ducts have been damaged, you’ll need to replace them. The national average air duct replacement cost is $150-$280, which may not include materials. Factors such as duct material, labor, location of ducts and linear feet of ductwork will all affect your final costs. Labor costs will vary based on how accessible the ducts are and what material your ducts are made of. The least expensive duct material is a flexible, non-metallic ducting that costs approximately $1-$2 per linear foot. Flexible aluminum is generally more expensive and stronger than non-metallic ducting. Stainless steel ducting is the strongest, the least flexible (meaning installing it typically has higher labor rates), and usually the most expensive. An average price for air duct replacement could range between $35 and $55 per linear foot, including basic materials and labor. A typical single-family home has 6-10 duct runs; replacing or installing one duct run could average $150-$250 for labor.
Should you need to replace an air conditioning unit, Abacus Plumbing recommends Lennox brand of air conditioning and heating systems. Lennox systems offer the highest level of home comfort at the lowest possible cost of operation. Additionally, these systems are praised by consumer publications and meet or exceed all government standards for efficiency. Learn more about installation »
Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]
We are large enough to service you with prompt service and best prices, but small enough to provide you with that personalized service you deserve. Our offices serve all of Hillsborough, Pinellas, Pasco, Polk, Sarasota, Manatee, Charlotte, Hernando & Citrus counties. Serving Tampa, St Petersburg, Clearwater, Lakeland, Sarasota, Bradenton, Temple Terrace, Brandon, Apollo Beach, Riverview, Valrico, Lithia, Palm Harbor, Plant City, Lutz, Wesley Chapel, Land o Lakes, Port Richey, Spring Hill, and all surrounding areas.

Believe it or not, the evaporator coils inside the AHU (Air Handling Unit) are freezing. You may notice the refrigerant lines on the condenser or at the AHU are frozen with ice build-up. The frost or ice builds up on the evaporator coils and blocks air flow (low air flow and no cooling are a sign of a low charge). A low refrigerant charge will cause the evaporator coil to operate at or below freezing. Since the coil typically operates below the dew point, it draws condensation out of the air. When the evaporator coil begins operating below freezing all this condensation freezes to the evaporator coil and the unit stops cooling.

When you trust your winter comfort to Edwards Heating & Air, we answer with state-of-the-art technology, NATE-certified technicians, and prompt action.  As a Carrier Factory Authorized Dealer, we specialize in the most proven and sophisticated solutions to home and commercial temperature control.  Through ongoing factory training and strict installation and service procedures, the team from Edwards Heating & Air delivers superior workmanship and superior results.  We ensure your demands for efficiency, reliability, and consistent heating are met, and your expectations for courteous and skilled service are exceeded.  Whether you are in the process of building your dream home, in need of effective heating for your existing home or business, or upgrading your furnace or heat pump, our installation specialists provide informed recommendations, attention to detail, and quick turnaround on your project.  Serving Acworth and the surrounding areas of Acworth, Alpharetta, Cummings, Cartersville, Kennesaw & Woodstock, GA since 2001, you can count on Edwards Heating & Air for everything from installation and maintenance to emergency repairs.


This is a very common air conditioning problem. The unit will cool for a few hours and then it stops cooling all together. The next day or several hours later the air conditioning is cooling again but for only a few hours and then the air conditioning stops again. The reason this is happening is because the air conditioning unit is low on refrigerant because you have a refrigerant leak (the unit could freeze because of a few other air conditioning problems but this is the most common reason).

I'm very glad that I found another guy to come replace the circuit board and put it away from the water, fix the water leak, and also find and fix another impending failure.  All of that was for much less than HVAC Service wanted to charge for repair or replacement. The other guy did a great repair, so I'm confident it will not break down again, but if it does, I will not call HVAC Service. Don't get suckered by their Yelp Deal.


"HVAC Service" has found success throughout the years by evaluating overall system performance, ease of installation, reliability and long term energy consumption costs, and how these variables relate to an owner's needs.  Through innovative engineering, comprehensive design solutions, consistent work quality, and qualified maintenance; "HVAC Service" confidently delivers the best possible solutions for your business.

In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.
The 2nd-century Chinese mechanical engineer and inventor Ding Huan of the Han Dynasty invented a rotary fan for air conditioning, with seven wheels 3 m (10 ft) in diameter and manually powered by prisoners of the time.[6] In 747, Emperor Xuanzong (r. 712–762) of the Tang Dynasty (618–907) had the Cool Hall (Liang Dian 涼殿) built in the imperial palace, which the Tang Yulin describes as having water-powered fan wheels for air conditioning as well as rising jet streams of water from fountains. During the subsequent Song Dynasty (960–1279), written sources mentioned the air conditioning rotary fan as even more widely used.[7]
With our wide range of expert services, affordable pricing, and customer dedication, we are certain to satisfy. This is all to ensure you only need to keep one number in mind for all your heating and cooling solutions. That number is 630-723-7716! Contact us today for new design/installation, replacement, seasonal maintenance, and/or prompt repair of furnaces, boilers, central air conditioners, ductless systems and so much more. After more than thirty years in business, Apex Energy, Inc. knows how to treat you right.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
×