Denver HVAC Repair

Modern refrigerants have been developed to be more environmentally safe than many of the early chlorofluorocarbon-based refrigerants used in the early- and mid-twentieth century. These include HCFCs (R-22, as used in most U.S. homes before 2011) and HFCs (R-134a, used in most cars) have replaced most CFC use. HCFCs, in turn, are supposed to have been in the process of being phased out under the Montreal Protocol and replaced by HFCs such as R-410A, which lack chlorine.[14] HFCs, however, contribute to climate change problems. Moreover, policy and political influence by corporate executives resisted change.[15][16] Corporations insisted that no alternatives to HFCs existed. The environmental organization Greenpeace provided funding to a former East German refrigerator company to research an alternative ozone- and climate-safe refrigerant in 1992. The company developed a hydrocarbon mix of isopentane and isobutane, but as a condition of the contract with Greenpeace could not patent the technology, which led to its widespread adoption by other firms.[17][18][19] Their activist marketing first in Germany led to companies like Whirlpool, Bosch, and later LG and others to incorporate the technology throughout Europe, then Asia, although the corporate executives resisted in Latin America, so that it arrived in Argentina produced by a domestic firm in 2003, and then finally with giant Bosch's production in Brazil by 2004.[20][21]
An important component of natural ventilation is air change rate or air changes per hour: the hourly rate of ventilation divided by the volume of the space. For example, six air changes per hour means an amount of new air, equal to the volume of the space, is added every ten minutes. For human comfort, a minimum of four air changes per hour is typical, though warehouses might have only two. Too high of an air change rate may be uncomfortable, akin to a wind tunnel which have thousands of changes per hour. The highest air change rates are for crowded spaces, bars, night clubs, commercial kitchens at around 30 to 50 air changes per hour.[17]
The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.

Kitchen & DiningBakeware,Coffee, Tea, & Espresso,Cookboo...19737 LuggageBackpacks,Briefcases & Laptop Bags,Carry...2666 Mattresses & AccessoriesMattress Toppers & Pads,Mattresses489 Office & School SuppliesDesk Accessories,Home Office Furniture,N...11964 Outdoor DécorDoormats, Flags & Wind Chimes,Lighting,P...15955 Patio & GardenBird Feeders & Food,Fire Pits & Outdoor...24762 Seasonal DécorChristmas,Easter,General Seasons,Hallowe...13503 Storage & OrganizationBathroom Storage,Closet Storage,Entryway...5296
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.

Beyond changing the air filter on a regular basis, one of the best ways to ensure your home's HVAC system is operating at peak efficiency is to have a qualified professional HVAC contractor tune up the system on a biannual basis. Energy Star recommends scheduling your system tune-up around the beginning of daylight savings time in the fall and its end in the spring. It's an easy way to remember to have your system serviced before the peak heating and cooling seasons. A standard tune-up is likely to cost you between $70 and $100, but it's money well spent. 

Hii need you guys help! Once my thermostat drop below the set temp , my furnace does not turn on and I was wondering what’s wrong with it. It happens mostly on cold nights. Sometimes I would have to go in the basement and turned the furnace power switch off then on and will come on once I switch it off then on.i also change the thermostat recently, so I don’t think that’s the problem
In the fall you should prepare your HVAC unit for winter. Turn off your air conditioner’s circuit, then hose it off to remove debris. It must dry completely. Do this when it’s warm enough that there’s no risk of the water freezing. Cover the exposed pipes with foam pipe insulation ($1-$3), and protect your entire unit with a weatherproof cover ($20-$50).
Strongsville Heating & Air Conditioning simplifies the challenges of keeping a perfectly comfortable home. We provide convenience, cost-savings, and reliability using top of the line products, premium materials, highly skilled technicians and exceptional customer service. Whether you need a new heating/cooling installation, replacement, retrofit, routine maintenance, trustworthy repair or air quality options, count on our team of NATE-certified technicians to eliminate stress and maximize comfort. We protect your busy schedule with flexible appointments, prompt arrival and mess free completion. Strongsville Heating & Air Conditioning is always available to you for Emergency Service, 24 hours a day, 365 days a year across Strongsville & Surrounding Areas.
Heaters exist for various types of fuel, including solid fuels, liquids, and gases. Another type of heat source is electricity, normally heating ribbons composed of high resistance wire (see Nichrome). This principle is also used for baseboard heaters and portable heaters. Electrical heaters are often used as backup or supplemental heat for heat pump systems.
Air conditioning is common in the US, with 88% of new single-family homes constructed in 2011 including air conditioning, ranging from 99% in the South to 62% in the West.[50] In Canada, air conditioning use varies by province. In 2013, 55% of Canadian households reported having an air conditioner, with high use in Manitoba (80%), Ontario (78%), Saskatchewan (67%), and Quebec (54%) and lower use in Prince Edward Island (23%), British Columbia (21%), and Newfoundland and Labrador (9%).[51] In Europe, home air conditioning is generally less common. Southern European countries such as Greece have seen a wide proliferation of home air-conditioning units in recent years.[52] In another southern European country, Malta, it is estimated that around 55% of households have an air conditioner installed.[53] In India AC sales have dropped by 40%[clarification needed] due to higher costs and stricter energy efficiency regulations.[54]
Protect your investment with HVAC services designed to create comfortable, energy efficient environments. National HVAC Service mechanical services safeguard against downtime and premature equipment failure while keeping facilities safe and comfortable. Our experienced HVAC technicians play a vital role in the daily operations of facility productivity and efficiency.
It’s a rare occasion for a problem to arise with your heating or cooling equipment at a convenient time. In fact, we’re not even certain such a time exists! That’s why the team at HVAC Unlimited stands ready to provide complete emergency heating and cooling repairs. No matter the time of day or the day itself, we can be on the way and ready to provide prompt, cost-efficient services to our Alexandria clients.

As a Bryant® dealer, with a wide variety of products to choose from, we can keep your family healthy and feeling comfortable all year long. We carry a complete line of indoor comfort equipment with innovations that raise the standards of comfort and reliability, including air conditioners, heat pumps, gas furnaces, programmable thermostats, humidifiers, ductless split systems, geothermal systems, boilers, air cleaners, ultra violet lights, ventilators and zoning products. Let the experts at HVAC Services Unlimited, Inc. help you customize a solution that's right for you.
Tony from HVAC came out on Sunday morning and did a fantastic job of immediately diagnosing the issue, quickly fixing the problem, and honoring the coupons I had. When I initially called on Saturday morning, I had a lot of trouble with their answering service getting their wires crossed with their technicians. However, Tony called me back and made it right. He even pointed out an issue that is in the horizon that I should look at (without charging me extra or telling me I had to fix it right now). Great service!
The content of this blog is intended for informational purposes only. Renovate America provides no endorsement and makes no representations as to accuracy, reliability, completeness, suitability or validity of any information or content on, distributed through or linked, downloaded or accessed from this site. This blog is subject to the additional terms found at https://www.renovateamerica.com/blog-disclaimer.

Fast forward 1 year and 1 week and the circuit board that HVAC Service had installed has failed again. They came out and said that it failed from water condensation dripping onto it, so we needed to replace it and reroute the pipes to prevent future water damage.  That would cost double what I paid last year.  Why didn't they fix the problem last year at the initial repair instead of putting in a circuit board that was bound to fail again?!? They were strongly recommending that the furnace be completely replace for a huge fee to avoid the same thing happening again.  I paid $59 for them to tell me they didn't fix it right last year. This didn't feel right, so I sought a second opinion.


Outside of your home is an outdoor unit, which is called a condenser. Inside the condenser is a compressor, a condenser coil, and a large fan. The compressor pumps cool refrigerant to an evaporator coil located either in the air handler or just outside the furnace. The evaporator coil gets really cold so that when the blower or furnace pushes warm air past it, the air is cooled. This cool air is then distributed throughout your home through a series of air ducts. Heat is absorbed by the evaporator coil, which warms the refrigerant moving through the coils. This warm refrigerant is then pumped back outside to the condenser coil, where a giant fan cools it off allowing the warm air to escape. This cycle is repeated until your thermostat detects that your home has reached the temperature you set it to.
Before you service an air conditioner, make sure the unit is turned completely off by unplugging or shutting off the circuit breaker. Then, rake off any debris from the unit and use a soft brush to remove dirt from the outside cover. If the small copper pipe connecting the unit to the house feels hot, the unit’s coils likely needs to be washed. Remove the outside cover, cover the motor and wiring with a plastic sheet, and hose down the fins, coils, and inside of the unit. Finally, replace the cover when you’re done.
From Day 1, Alberto walked us through the process, and present us with a variety of options based our budget for the project. His customer service is the best as he did not oversell any services and did not nudge us towards buying a unit that would stretch our budget. On installation day, HVAC Services sent out a crew of 6-7 guys, all of whom were very polite and kept their work areas clean, and installed the whole system the same day.
A home HVAC system tends to break down when you need it the most–either during a cold winter night or a sweltering summer afternoon. During times of great need, 24-hour emergency service is available (and are guaranteed for members of our HVAC service plans). For most HVAC calls, our technicians will have everything they need in their well-stocked van to fix what is broken that day.
   As for parts prices, we are a business and factor in profit and overhead into our pricing structure, and frequently research other companies to be sure we are competitive, which we are. Jody, you did not pay $400 for labor, you paid $489 for a flat rate repair which included, travel, labor, diagnostics, parts, tax, shipping, truck charge, fuel charge, overtime rate, profit and overhead. As for the time of the actual repair, if it had taken 2 or 3 hours the cost would have still been the same $489.        

We are large enough to service you with prompt service and best prices, but small enough to provide you with that personalized service you deserve. Our offices serve all of Hillsborough, Pinellas, Pasco, Polk, Sarasota, Manatee, Charlotte, Hernando & Citrus counties. Serving Tampa, St Petersburg, Clearwater, Lakeland, Sarasota, Bradenton, Temple Terrace, Brandon, Apollo Beach, Riverview, Valrico, Lithia, Palm Harbor, Plant City, Lutz, Wesley Chapel, Land o Lakes, Port Richey, Spring Hill, and all surrounding areas.
Believe it or not, the evaporator coils inside the AHU (Air Handling Unit) are freezing. You may notice the refrigerant lines on the condenser or at the AHU are frozen with ice build-up. The frost or ice builds up on the evaporator coils and blocks air flow (low air flow and no cooling are a sign of a low charge). A low refrigerant charge will cause the evaporator coil to operate at or below freezing. Since the coil typically operates below the dew point, it draws condensation out of the air. When the evaporator coil begins operating below freezing all this condensation freezes to the evaporator coil and the unit stops cooling.
Berkeys knows how unbearable the Dallas, Plano, Fort Worth and Arlington Texas summers can be. Assuring your home’s air conditioning system is functioning properly is our job! We’ll always have the solution to your air conditioning problem, and we’ll rescue you when your system stops working. Call us or schedule your service online today and we think you will see why we are considered to be one of the Best A/C Companies in the Dallas & Fort Worth area!
If the AC doesn’t turn off, it may be time to clean the condensing unit. Dirty condenser coils won’t give off heat efficiently and will keep the unit running.  Another possibility: The contacts on the outdoor run relay may have welded together—something that can happen over time because of frequent electrical arcing at the relay. Before checking the run relay, turn off the power to the furnace and the condensing unit. Next, disassemble the relay and pry apart the contacts. This should do the trick until you buy a replacement—which you should do soon.
James Heating & A/C, Inc offers furnace service appointments that help keep your furnace in tip-top shape and operating efficiently for you all winter long. Whether that’s finding small issues before they become big problems, identifying potential safety hazards or making sure you’re maintaining your manufacturer’s warranty, our experts have you covered. Our trained technicians complete furnace service with care, inspecting a number of components in and around your furnace. In fact, our multi-point inspection can help make sure your system runs smoothly throughout the winter.
All your HVAC needs are addressed, including finding a local heating and air conditioning contractor in your area. We offer information for a variety of brands and products in the HVAC industry, so you can care for your heating and cooling system, or know when to call a licensed HVAC contractor to repair your HVAC system. Get knowledgeable advice from the experts at HVAC.com today!

I took off stars for two reasons. Minus one star for issues trying to use the $50 for $25 voucher I purchased through Yelp. Although there was no minimum stipulated, the office wouldn't take it for the initial $59 diagnostic fee. If I used the 10% off First service that they offer, then they won't let me use the voucher on the actual repair bill.  I was stuck with paying the full $59 diagnostic fee.
ISO 16813:2006 is one of the ISO building environment standards.[27] It establishes the general principles of building environment design. It takes into account the need to provide a healthy indoor environment for the occupants as well as the need to protect the environment for future generations and promote collaboration among the various parties involved in building environmental design for sustainability. ISO16813 is applicable to new construction and the retrofit of existing buildings.[28]

Tony from HVAC came out on Sunday morning and did a fantastic job of immediately diagnosing the issue, quickly fixing the problem, and honoring the coupons I had. When I initially called on Saturday morning, I had a lot of trouble with their answering service getting their wires crossed with their technicians. However, Tony called me back and made it right. He even pointed out an issue that is in the horizon that I should look at (without charging me extra or telling me I had to fix it right now). Great service!
Even if your air conditioning unit is still working, depending on the type of system in your home today, you could recoup your investment in a new system in as little as three years. However, that doesn't mean that your system needs to be replaced. Furnaces, air conditioners, and other heating and cooling systems have made tremendous gains in efficiency over the past five years, so if you have an older unit, it is worth taking a look at whether or not a repair is the best investment.

“Robinson Air = top notch professionals. Mike was personable, knowledgeable, timely, thorough, and left me with a hard copy of prioritized recommendations and his explanations of HVAC needs I may have in the future. I was very impressed with being shown a tablet picture of a possible problem. It was so refreshing to have the service and all phone interactions handled so well and smoothly…thank you for taking the “angst” out of this kind of service call. My hat is off to you and I will happily recommend you to family and friends. Thank you!!!”

SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
If the AC doesn’t turn off, it may be time to clean the condensing unit. Dirty condenser coils won’t give off heat efficiently and will keep the unit running.  Another possibility: The contacts on the outdoor run relay may have welded together—something that can happen over time because of frequent electrical arcing at the relay. Before checking the run relay, turn off the power to the furnace and the condensing unit. Next, disassemble the relay and pry apart the contacts. This should do the trick until you buy a replacement—which you should do soon.
If your air ducts have been damaged, you’ll need to replace them. The national average air duct replacement cost is $150-$280, which may not include materials. Factors such as duct material, labor, location of ducts and linear feet of ductwork will all affect your final costs. Labor costs will vary based on how accessible the ducts are and what material your ducts are made of. The least expensive duct material is a flexible, non-metallic ducting that costs approximately $1-$2 per linear foot. Flexible aluminum is generally more expensive and stronger than non-metallic ducting. Stainless steel ducting is the strongest, the least flexible (meaning installing it typically has higher labor rates), and usually the most expensive. An average price for air duct replacement could range between $35 and $55 per linear foot, including basic materials and labor. A typical single-family home has 6-10 duct runs; replacing or installing one duct run could average $150-$250 for labor.

The myth that most people believe is that if you add more refrigerant to the unit it will cool better. This is only true if the evaporator coil is operating below freezing. The unit must have a balanced charge at the correct refrigerant pressure for the temperature and usually, only an HVAC professional can charge your unit properly. Another misconception about refrigerant is that the unit burns it up and it must be replaced from time to time. This is not true. Furthermore, the refrigerant loop is a closed system and barring any leaks the air conditioning system should never need any refrigerant.
This company deserves more than five stars. They didn't just replace my heater and air conditioner, they built me a new system for my house. Going above and beyond is a understatement. Steve's staff were 2 of the nicest workers I've come across in a long time. Friendly, knowledgeable, and very clean. Truly a top rated company. Thanks Steve. Great job.
Believe it or not, the evaporator coils inside the AHU (Air Handling Unit) are freezing. You may notice the refrigerant lines on the condenser or at the AHU are frozen with ice build-up. The frost or ice builds up on the evaporator coils and blocks air flow (low air flow and no cooling are a sign of a low charge). A low refrigerant charge will cause the evaporator coil to operate at or below freezing. Since the coil typically operates below the dew point, it draws condensation out of the air. When the evaporator coil begins operating below freezing all this condensation freezes to the evaporator coil and the unit stops cooling.
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
×